Please enable JavaScript to view this site.

120 Machine Manual

Navigation: Operator Control Panel (HMI) > HMI Main Screen > Data Input Page > Cam Data Page

Solenoid Valve Cams

**User Level 3 is required for this feature**

**Changes made on this page will only affect the current downloaded product**

Scroll Prev Top Next More

Solenoid Valve Cams

The solenoid valve cams should be altered on the Cam Data Page. The Slave Pos. row contains the data that will energize or not energize the solenoid valve. The Master Pos. row contains the master's position at each function of the solenoid valve.

 

Solenoid Master Pos. - Master's Position of each slave position.

Solenoid Slave Pos.

oSpring Return or Vacuum Solenoid Valve - 1 will energize and 0 will not energize

oDouble Detent Solenoid Valve - 1 will energize and -1 will not energize

 

 

Example Cam in above screen - At point 1 the master position is 0 and the slave position is 0 which is not energized. Point 1 should always be master position 0 in order to know the solenoid valve's position at the start of the cycle. At point 2 the master position is 5 and the slave position is 1 which is energized. At point 3 the master position is 10 and the slave position is 0 which is not energized.