Alarms - Integrated Devices
Stop Alarm |
Alarm Diagnostics |
Cause |
Remedy |
---|---|---|---|
EM Alarm |
Glue Tank Faulted |
Glue Tank is Faulted |
Refer to the Glue Tank Display and Glue System Manual |
Glue Tank Not Ready |
Glue Tank has not reach operating temperature |
Wait for temperature of glue system to reach operational temperature |
|
MT Vacuum Pump Alarm |
Fwd Sensor Jam |
The forward sensor signal was lost for longer than the jam time while the forward direction is commanded |
Remove the object which caused the motor to slow down |
Fwd Sensor Not Made In Time |
The forward sensor was not made before the forward Time limit was exceeded when the forward direction was commanded |
Remove the object which prevented the motor from making the sensor |
|
Fwd Sensor On Too Long |
Fwd sensor was made longer than the Fwd Time limit when the Forward was commanded to be de-energized |
Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly |
|
Overload Fault |
The overload sensing device has been tripped |
Manually reset the device |
|
Rev Sensor Jam |
The reverse sensor signal was lost for longer than the jam time while the reverse direction is commanded |
Remove the object which caused the motor to slow down |
|
Rev Sensor Not Made In Time |
The reverse sensor was not made before the reverse Time limit was exceeded when the reverse direction was commanded |
Remove the object which prevented the motor from making the sensor |
|
Rev Sensor On Too Long |
Rev sensor was made longer than the Rev Time limit when the Reverse was commanded to be de-energized |
Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly |
|
SV Blow Off Alarm |
A Sensor Jam |
The A sensor signal was lost for longer than the jam time while the A coil is commanded to be energized and the A sensor was made |
Check sensor for proper operation |
A Sensor Not Made In Time |
The A sensor was not made before the A Time limit was exceeded when the A Coil was commanded to be energized |
Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly |
|
A Sensor On Too Long |
The A sensor was made longer than the A Time limit when the A Coil was commanded to be de-energized |
Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly |
|
B Sensor Jam |
The B sensor signal was lost for longer than the jam time while the B coil is commanded to be energized and the B sensor was made |
Check sensor for proper operation |
|
B Sensor Not Made In Time |
The B sensor was not made before the B Time limit was exceeded when the B Coil was commanded to be energized |
Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly |
|
B Sensor On Too Long |
B sensor was made longer than the B Time limit when the B Coil was commanded to be de-energized |
Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly |
|
Warning |
|
Cause |
Remedy |
Glue Tank Not Ready |
|
Glue system not up to operating temperature |
Wait for glue system to reach operating temperature |
Low Glue Level |
|
Glue tank is low in adhesive |
Fill glue tank with more adhesive |
No Vacuum Supply |
|
Vacuum supply is not supplying sufficient vacuum for continued operation |
Supply sufficient vacuum |