Aagard Machine Manual

Alarms - Integrated Devices

Hide Navigation Pane

Alarms - Integrated Devices

Previous topic Next topic No directory for this topic No expanding text in this topic  

Alarms - Integrated Devices

Previous topic Next topic Topic directory requires JavaScript JavaScript is required for expanding text JavaScript is required for the print function  

Stop Alarm

Alarm Diagnostics

Cause

Remedy

EM Alarm

Glue Tank Faulted

Glue Tank is Faulted

Refer to the Glue Tank Display and Glue System Manual

Glue Tank Not Ready

Glue Tank has not reach operating temperature

Wait for temperature of glue system to reach operational temperature

MT Vacuum Pump Alarm

Fwd Sensor Jam

The forward sensor signal was lost for longer than the jam time while the forward direction is commanded

Remove the object which caused the motor to slow down

Fwd Sensor Not Made In Time

The forward sensor was not made before the forward Time limit was exceeded when the forward direction was commanded

Remove the object which prevented the motor from making the sensor

Fwd Sensor On Too Long

Fwd sensor was made longer than the Fwd Time limit when the Forward was commanded to be de-energized

Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly

Overload Fault

The overload sensing device has been tripped

Manually reset the device

Rev Sensor Jam

The reverse sensor signal was lost for longer than the jam time while the reverse direction is commanded

Remove the object which caused the motor to slow down

Rev Sensor Not Made In Time

The reverse sensor was not made before the reverse Time limit was exceeded when the reverse direction was commanded

Remove the object which prevented the motor from making the sensor

Rev Sensor On Too Long

Rev sensor was made longer than the Rev Time limit when the Reverse was commanded to be de-energized

Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly

SV Blow Off Alarm

A Sensor Jam

The A sensor signal was lost for longer than the jam time while the A coil is commanded to be energized and the A sensor was made

Check sensor for proper operation

A Sensor Not Made In Time

The A sensor was not made before the A Time limit was exceeded when the A Coil was commanded to be energized

Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly

A Sensor On Too Long

The A sensor was made longer than the A Time limit when the A Coil was commanded to be de-energized

Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly

B Sensor Jam

The B sensor signal was lost for longer than the jam time while the B coil is commanded to be energized and the B sensor was made

Check sensor for proper operation

B Sensor Not Made In Time

The B sensor was not made before the B Time limit was exceeded when the B Coil was commanded to be energized

Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly

B Sensor On Too Long

B sensor was made longer than the B Time limit when the B Coil was commanded to be de-energized

Remove the object which is hindering the motion, or repair the device which is wearing out causing the motion from being executed properly

Warning

 

Cause

Remedy

Glue Tank Not Ready

 

Glue system not up to operating temperature

Wait for glue system to reach operating temperature

Low Glue Level

 

Glue tank is low in adhesive

Fill glue tank with more adhesive

No Vacuum Supply

 

Vacuum supply is not supplying sufficient vacuum for continued operation

Supply sufficient vacuum