Solenoid Valve Jog & Config Data
NOTE: The machine must be started in manual mode in order to jog a drive
Jog
A Coil Button
Tap this button to energize the A Coil of the solenoid valve and de-energize the B Coil.
Stop Button
Tap this button to de-energize the A and B Coils.
B Coil Button
Tap this button to energize the B Coil of the solenoid valve and de-energize the A Coil.
Configuration Data
A Time (ms)
This entry field specifies the amount of time allowed for the solenoid valve to energize the A Sensor before causing a fault, in milliseconds.
B Time (ms)
This entry field specifies the amount of time allowed for the solenoid valve to energize the B Sensor before causing a fault, in milliseconds.
Debounce Time (ms)
This entry field specifies the amount of time the sensor must be true before being considered a valid signal, in milliseconds.
Jam Time (ms)
This entry field specifies the amount of time the sensor signal may be false when the signal should be true before causing a fault, in milliseconds.
Status Indicators
A Sensor
This indicator displays if the A Sensor is energized.
B Sensor
This indicator displays if the B Sensor is energized.
Done
This indicator displays when the valve has reached its final state.
Error
This indicator displays if there was a malfunction in its operation.