TIP REJECT

 

Tip/Reject Conveyor Speed (FPM)

This field specifies the speed of the Tip/Reject Conveyor. The unit of measure for this entry field is Feet Per Minute (FPM).

 

Drop Product Stop Position (Master Position)

This entry field specifies the Master Position of the Tip/Reject Master where the Product Stop is dropped. The unit of measure for this entry field is in the Master Position of the Tip/Reject Master.

 

Re-Enable Tip/Reject Conveyor (Master Position)

This entry field specifies the Master Position of the Tip/Reject Master where the Tip/Reject Conveyor is turned on.  The unit of measure for this entry field is in the Master Position of the Tip/Reject Master.

 

ROTATE AND ACCUMULATION

 

Rotate Cases

This check box allows for the Case Rotate to be enabled on the sizes where the case needs to be rotated in order to obtain the correct orientation.

 

Begin Rotate Delay Time (Time in Seconds)

This field specifies the time between when a product is sensed and the rotate cycle begins. The unit of measure for this entry field is Seconds (Sec).

 

Release Vacuum Early Distance (Degrees)