ZSE40 Vacuum Switch Setup:
1) | In the Aagard wiring diagram, find the correct ON and OFF trigger values |
2) | Press and hold the SET button until a unit of measure is displayed (example KPa) |
3) | Use the UP and DOWN buttons to navigate until inH is displayed (inches of mercury) |
4) | Press and release the SET button; this will set inH as the unit of measure and the display should show a low number as the current reading |
5) | Press and release the SET button; the display should toggle between P_1 and a number |
6) | Use the arrow buttons to adjust the number of the ON trigger value (example -15.0) |
7) | Press and release the SET button; the display should toggle between P_2 and a number |
8) | Use the arrow buttons again to adjust the number of the OFF trigger value (example -12) |
9) | Press and release the SET button; the display will toggle between P_3 and a number |
10) | The default value is used for P_3; press/release the SET button to go to P_4 |
11) | Again, the default value is used for P_4; press/release the SET button until the display is back to the main page, which should be showing a low number reading |
The OUT 1 indicator should not be illuminated, and you are ready for production. The vacuum switch will provide an output when vacuum gets to the ON trigger value (example -15.0) and will not turn off the output unless the vacuum drops below the OFF trigger value (example -12.0).
ZSE40A Vacuum Switch Setup:
1) | In the Aagard wiring diagram, find the correct P1 and H1 values |
2) | Press and hold the SET button until a function is displayed (example F 0) |
3) | Use the UP and DOWN buttons to navigate until Uni is displayed |
a) | Use the UP key to set display to inH (inches of mercury) |
4) | Press and release the SET button; this will set inH as the unit of measure and the display should show a low number as the current reading |
5) | From F 0, press the UP key once to navigate to F 1 |
a) | Press the SET button 3 times so the display reads P_1 |
6) | Use the UP and DOWN buttons to adjust the set point to what is stated on the wiring diagram |
7) | Press the SET button 1 more time so the display reads H_1 |
8) | Use the UP and DOWN buttons to set the display to 3.0 |
9) | Press SET button 2 times to return to F 1 |
10) | Press and hold the SET button until the display is back to the main page; the main display should be showing a low number reading |
The OUT 1 indicator should not be illuminated, and you are ready for production. The vacuum switch will provide an output when vacuum gets to the ON trigger value (example -15.0) and will not turn off the output unless the vacuum drops below the OFF trigger value (example -12.0).