Cause |
Remedy |
||||
---|---|---|---|---|---|
B1 |
Bus Coupler |
Read IDN Error |
Unable to read the parameter from the brick |
Use error id to find more details in the Beckhoff Information System |
Warning |
C20 4 |
SD Reference |
Probe Sensor Not Found |
The probe sensor was not detected during the reference routine |
Check the probe sensor and the probe setup data |
Fault |
CR40201 |
Software Emergency Stop |
Not Ready |
A condition in the PLC is requiring a software emergency stop |
Check reasons for PLC emergency stop condition |
General |
ES24305 |
CP Remote System E Stop |
Pulled |
The emergency stop button is released |
No action required |
General |
GR22401 |
Sleever Guard Relay |
Guard Relay Reset Failed |
A check was performed after all guard doors in this circuit were closed to see if the guard relay was reset; this check failed |
If problem persists, check guard circuit |
Warning |
GS22503 |
Guard Door 4 |
Closed |
Door is closed |
No action required |
General |
GT9401 |
Glue System |
Low Glue Level |
The glue level is low |
Fill glue tank |
General |
MT306 |
System Vacuum Pump |
Input Parameter Error |
The configuration data for the motor is incorrect |
Fix data configuration, check programming |
Fault |
PB41301 |
CP Remote System Start |
Released |
Button is released |
No action required |
General |
PE41705 |
Manufacturer Flap |
Reject Detected |
Manufacturer's Flap PE was blocked in end compression station |
Make sure Manufacture Glue gun is working properly and nothing is blocking the PE or Reflector |
Reject |
PS36502 |
Dumped Air Pressure |
Low Air Pressure |
Air pressure is low |
Check air pressure |
General |
SM18 SM19 SM20 SM21 SM22 SM23 SM24 SM25 SM26 SM27 SM28 SM29 SM30 |
Loader Loader Z-Axis Case Setup Case Flights Flap Traps Fixed Funnel Adjustable Funnel Load Side Tucker Non Load Side Tucker Case Squaring Manufacturer Glue End Flap Compression Mfr Flap/Top Tucker |
Fast Stop Failed |
The drive was not able to fast stop successfully |
Clear message and start system; if problem persists, review move data |
Fault |
SR28201 |
Customer Global Safety Relay |
Safety Relay Reset Check Failed |
A check was performed after the safety circuit was reset to see if the relay is reset; this check failed |
If problem persists check safety circuit |
Warning |
SV50602 |
Upper Glue Load Side |
Direction A Sensor Not Made In Time |
The A sensor did not make in the required time from the A direction call |
Check A sensor for proper operation |
Fault |
TS37102 |
Remote HMI Cabinet Temp Sensor |
Above Set Point |
The cabinet temperature is above the set point |
Check the cabinet for excessive heat, verify cooling system is properly functioning, check temp switch for proper operation |
General, Warning |
VS36503 |
System Vacuum |
Low Vacuum Supply |
Vacuum was lost when not expected |
Check vacuum supply |
Fault |