Replacement

 

Tools Required:

 

Adjustable Wrench

 

Routine:

 

1)Turn off main air
2)Disconnect the electrical wire on the sensor
3)Loosen the sensor using the crescent wrench
4)Remove the sensor and replace with the new one (be sure to use thread tape)
5)Tighten the sensor down so it’s easily readable
6)Reconnect the electrical wire on the sensor
7)Turn on main air

 


 

ISE40A Pressure Switch Setup (A model only):

 

1)Enter Function Selection mode – Press and hold the S key (> 2 sec.) until the display reads F 0
2)From F 0 press the UP button to navigate to F 1 and press the S key 3 times until the display reads P_1
3)Using the UP and DOWN buttons set display to the setting on the Aagard wiring diagram (Aagard standard setting is 65 psi)
4)Press the S key once to display H_1
a)Using the UP and DOWN buttons set display to 1.0
b)Press the S key 2 times to return to F 1.
5)Return to the main display by pressing and holding the S key for > 2 seconds; the main display should be showing a low number reading

 

NOTE: The Out 1 indicator should not be illuminated at this point if system air has not yet been applied

 

System pressure switch settings – P_1 = 65.0

 

By setting the ISE40A switch up in this manner, the pressure switch will provide an output when system pressure gets to 65.0 PSI; it will loose its signal when it drops below 64.0 PSI.