1) | While the machine is running, click on the Enable Case Refeed Mode Button on the Auxiliary Operations screen or select the Case Refeed selector switch at the case refeed station |
2) | Wait for upstream Aagard equipment to enter State: Held |
a) | Any downstream Aagard equipment will continue to run |
3) | While the upstream Aagard equipment is in State: Held, the Case Reject Clear photo eye is disabled |
a) | If equipped, the Z-Axis Tipper robot is retracted |
4) | Reach through the Case Reject Chute and place the case against the backstop in the same orientation in which it was AFTER the case was tipped |
5) | When finished, click on the Enable Case Refeed Mode Button; the machine will resume normal operation |
NOTE: On some Aagard systems, this button is located on the HMI Main Screen